| 3.2 LiFePo4 | 3.7V Lithium iron |
| 4S 350A Same | 3S 350A Same |
| 8S 350A Same | 7S 350A Same |
| 12S 350A Same | 10S 350A Same |
| 16S 350A Same | 13S 350A Same |
| 20S 350A Same | 17S 350A Same |
| 24S 350A Same | 20S 350A Same |
| 28S 350A Same | 24S 350A Same |
| 32S 350A Same | 28S 350A Same |
| 30S 350A Same | |
| 32S 350A Same | |
| 35S 350A Same |
| Brand Name: | HeltecBMS |
| Material: | PCB board |
| Origin: | Mainland China |
| Warranty: | One year |
| MOQ: | 1 pc |
| Battery Type: | 3.2V LFP / 3.7V NMC |
| Balance type: | Passive balancing |
1. 350A Relay BMS * 1set. (Other parts according to your needs)
2. Anti-static bag, anti-static sponge and corrugated case.
|
Technical Index |
Parameters |
||||
|
Standard Continuous Current |
60A |
120A |
150A |
200A |
500A |
|
Continuous Current Data |
Data with a temperaure not hight than 60℃ for 5 minutes in an open space at room temperature of 20℃ |
||||
|
Main Circuit On-Resistance |
<2.8mR |
<1.9mR |
<1.5mR |
<1.2mR |
<0.3mR |
|
Charging Current (Same Port) |
60A |
120A |
150A |
200A |
500A |
|
Discharge Current (Same Port) |
60A |
120A |
150A |
200A |
500A |
|
Standard Charging Voltage |
Ternary: 4.2V * String number |
||||
|
Operating Temperature |
-30~100℃ |
||||
|
Over-charge Voltage Protection |
|||||
|
Detection Voltage |
Ternary: 4.235±0.03V |
||||
|
Detection Delay |
500-1500ms |
||||
|
Release Voltage |
Ternary: 4.18±0.03V |
||||
|
Equalization Voltage |
|||||
|
Turn-on Voltage |
Ternary ≥ 4.19±0.03V |
||||
|
Release Voltage |
Ternary ≥ 4.19±0.03V |
||||
|
Balance Current |
100-500mA |
||||
|
Over-discharge Voltage Protection |
|||||
|
Detection Voltage |
Ternary: 2.8±0.1V |
||||
|
Detection Delay |
500-1500ms |
||||
|
Release Voltage |
Ternary: 3.00±0.1V |
||||
|
Discharge Over-current Protection |
|||||
|
Detection Current |
3 times the continuous current |
||||
|
Detection Delay |
100-400ms |
||||
|
Release Condition |
Disconnect Load/Charge Active |
||||
|
Short Circuit Protection |
|||||
|
Trigger Condition |
external load short circuit |
||||
|
Detection Delay |
150-600μs |
||||
|
Release Condition |
Disconnect Load/Charge Active |
||||
|
Temperature Control Protection |
|||||
|
Charge and Discharge Over Temperature Protection |
75±5℃ |
||||
|
Charge and Discharge High Temperature Release Temperature |
75±5℃ |
||||
|
Self Power Consumption |
|||||
|
Release Condition |
Disconnect Load/Charge Active |
||||
|
Working Power Consumption |
<80μA |
||||
|
Sleep and Overdischarge |
<50μA |
||||